Enmet SPECTRUM User Manual

Browse online or download User Manual for Measuring instruments Enmet SPECTRUM. ENMET SPECTRUM User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ENMET
ENMETENMET
ENMET Corporation
PO Box 979
Ann Arbor, MI 48106-0979
80012-011
December 1995
MCN-153; 04/22/96
MCN-157; 03/19/97
MCN-172; 06/12/97
MCN-187; 02/23/98
MCN-188; 03/26/98
MCN-204; 10/20/98
MCN-222; 11/12/99
MCN-228; 11/30/99
MCN-243; 09/25/00
MCN-259; 07/17/01
MCN-268; 11/05/01
MCN-276; 05/06/02
MCN-292; 02/14/03
MCN-301; 06/05/03
MCN-308; 10/16/03
MCN-311; 11/24/03
MCN-315; 02/12/04
MCN-348; 08/10/06
MCN-352; 10/06/06
SPECTRUM Series
Instrument Manual
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - SPECTRUM Series

ENMETENMETENMETENMET CorporationPO Box 979Ann Arbor, MI 48106-097980012-011December 1995MCN-153; 04/22/96MCN-157; 03/19/97MCN-172; 06/12/97MCN-187; 02

Page 2

ENMET Corporation SPECTRUM Series62.1.6 Battery Status and Low Battery AlarmsThe battery status display is accessed by pressing the OPTION pushbutton

Page 3 - List of Illustrations

SPECTRUM Series ENMET Corporation73.0 Maintenance3.0 Maintenance3.0 Maintenance3.0 Maintenance3.1 Maintenance MenuFrom the operational display, press

Page 4

ENMET Corporation SPECTRUM Series83.1.1 KeyEntrance to the maintenance menu is guarded with a four digit numerical key. The factory default setting o

Page 5 - 1.0 Introduction

SPECTRUM Series ENMET Corporation93.1.3 CalibrationNOTE: Calibration must be performed at normal room temperature (20-25°C) for optimal performance.

Page 6 - Top View

ENMET Corporation SPECTRUM Series103.1.5 Setting the Battery TypeA valid key entry sets the instrument at the "run ZERO" location of the mai

Page 7 - 2.0 Features and Operation

SPECTRUM Series ENMET Corporation113.2.2 Sensor Removal and ReplacementA low 9v battery may cause a “Cell Out” indication. Check or replace the 9v Ba

Page 8 - 2.1 Operation

ENMET Corporation SPECTRUM Series124.0 Replacement Parts and Accessories4.0 Replacement Parts and Accessories4.0 Replacement Parts and Accessories4.0

Page 9 - 2.1.5 Confidence Beep

SPECTRUM Series ENMET Corporation135.0 WARRANTY5.0 WARRANTY5.0 WARRANTY5.0 WARRANTYENMET warrants new instruments to be free from defects in workmansh

Page 10 - 2.2 Interference Gases

ENMET Corporation SPECTRUM Series14Appendix A: Calibration Data TablesAppendix A: Calibration Data TablesAppendix A: Calibration Data TablesAppendix A

Page 11 - 3.0 Maintenance

SPECTRUM Series ENMET Corporation15Table 2: Spectrum Calibration Voltage and Countdown TimesNOTE: The following are values used for production calibra

Page 13 - 3.1.3 Calibration

ENMET Corporation SPECTRUM Series16Appendix B: Interference GasesAppendix B: Interference GasesAppendix B: Interference GasesAppendix B: Interference

Page 14 - 3.2 Changing Components

SPECTRUM Series ENMET Corporation17SPECTRUM Series for CHLORINE (3E sensor)The following gases cause a reading:InterferantGas/VaporInterferant Concent

Page 15

ENMET Corporation SPECTRUM Series18SPECTRUM Series for Hydrogen Chloride (3E 30 sensor)The following gases cause a reading:InterferantGas/VaporInterfe

Page 16

SPECTRUM Series ENMET Corporation19SPECTRUM Series for Fluorine (3E 10 sensor)The following gases cause a reading:InterferantGas/VaporInterferant Conc

Page 17 - 5.0 WARRANTY5.0 WARRANTY

ENMET Corporation SPECTRUM Series20SPECTRUM Series for Nitric Oxide (3E 100 sensor)The following gases or vapors have been tested and do not cause a r

Page 18

SPECTRUM Series ENMET Corporation21SPECTRUM Series for Ozone (3E 1 sensor)The following gases cause a reading:InterferantGas/VaporInterferant Concentr

Page 19

ENMET Corporation SPECTRUM Series22SPECTRUM Series for Sulphur Dioxide(4S sensor)The following gases cause a reading:InterferantGas/VaporInterferant C

Page 20

SPECTRUM Series ENMET Corporation23SPECTRUM Series for Phosgene (3E sensor)The following gases cause a reading:InterferantGas/VaporInterferant Concent

Page 21

ENMET Corporation SPECTRUM Series24APPENDIX C APPENDIX C APPENDIX C APPENDIX C SPECTRUM for HydrazineSPECTRUM For HydrazineThe detection of hydrazine,

Page 22

PO Box 979680 Fairfield CourtAnn Arbor, Michigan 48106-0979734.761.1270 Fax 734.761.3220Returning an Instrument for RepairENMET instruments may be ret

Page 23

Table of Contents1.0 INTRODUCTION...

Page 25

Repair Return FormMailing Address:ENMET CorporationPO Box 979Ann Arbor, Michigan 48106Phone Number: 734.761.1270FAX Number: 734.761.3220Shipping Addr

Page 28 - APPENDIX C APPENDIX C

SPECTRUM Series ENMET Corporation11.0 Introduction1.0 Introduction1.0 Introduction1.0 IntroductionThe SPECTRUM is a small portable battery operated si

Page 29 - 734.761.1270 Fax 734.761.3220

ENMET Corporation SPECTRUM Series21.2 Turn Instrument ONTurn the instrument ON, by pressing and holding the POWER / BACKLIGHT pushbutton for two secon

Page 30

SPECTRUM Series ENMET Corporation32.0 Features and Operation2.0 Features and Operation2.0 Features and Operation2.0 Features and OperationThe features

Page 31 - Repair Return Form

ENMET Corporation SPECTRUM Series42.1 Operation2.1.1 Operational MenuThe operation menu flow diagram is shown in Figure 2. This menu is accessed with

Page 32

SPECTRUM Series ENMET Corporation52.1.2 Turn ON and OFFTurn the instrument ON by pressing the POWER / BACKLIGHT pushbutton for two seconds. For most